WebJan 7, 2024 · The welding/heating tips were not designed for inlet pressures at 150-200 psi. The acetylene regulators are typically 30 PSI (used at up to 15 psi) and dedicated propane torch regulators are usually a 50 psi regulator which you could use at 50 PSI but usually limited to about 25 psi for the same reasons I listed above being too sensitive to ... WebJun 2, 2011 · I have an oxy/acetylene set up. When I shut down, I turn off the tank valves, release the regulator pressure then purge the hoses. ... Leak can be at cylinder valve packing, cylinder valve / regulator connection, pressure gage, HP pipe threads, or through regulator. Can test this with leak detection solution. Remove hoses to check for leak ...
Smith Brand Regulators Oxygen Regulator Low Pressure for Oxy …
WebSep 24, 2024 · Oxy Acetylene Welding Set Up and Pressure Settings Chart : The first we must Clean the nozzle, because if the head of the nozzle dirty will cause flame bad. Open Regulator Oxygen and Acetylene, set until the pressure matching with what do you want or for acetylene 5 to 7 psi and Oxygen 7 to 10 psi. WebMar 3, 2024 · The Oxy-Acetylene welding equipment consists of oxygen and acetylene gas cylinders, pressure regulators, hoses, Flame Arrestors, welding torches, and economizers. Once you have a clear understanding of the equipment, you will know exactly how Oxy-Acetylene welding works. Gas Cylinders hydroxylamine-o-sulfonic acid amination
How to properly light, adjust and shut down an oxy–acetylene torch
WebThis method is necessary because above 207 kPa (30 lbf/in²) (absolute pressure) acetylene is unstable and may explode . There is about 1700 kPa (250 psi) pressure in the tank when full. Acetylene when combined with oxygen burns at 3200 °C to 3500 °C (5800 °F to 6300 °F ), highest among commonly used gaseous fuels. WebJun 4, 2024 · Oxygen is mixed with acetylene gas to produce the high heat. Brazing equipment includes: oxygen and acetylene cylinders, pressure regulators, hoses, fittings, safety valves, torches and tips. The regulator has two gauges, one to register tank pressure and the other to register pressure to the torch. WebMay 19, 2024 · Never use acetylene at pressures above 15 psig, as it becomes unstable above that pressure. Purge the system before use each day by bleeding off the hoses one at a time. No oil should be used in cleaning, assembling, or connecting the regulators, as this can provide fuel that ignites under oxygen re-compression. hydroxylamine medication